Description:
The FX500 is a microfluidics chip based cell sorter. Its fully replaceable fluidics system lets researchers easily replace the entire fluidics path to control sample-to-sample carryover. The FX500 features comprehensive fluidics controls, advanced automation and easy to use software.
Patented CoreFinder™ technology automates instrument setup and streamlines workflow. The optical design offers up to three collinear excitation lasers - 488 nm, 561 nm, and 638 nm and six fluorescence detectors. The six free-form PMTs enable detection of fluorescence signals from any laser-based on filter setting.
The FX500 is for non-clinical research use only and is a Class 1 laser product.
| Specifications | |
|---|---|
| Sorter/ Analyzer | 
                       Cell Sorters  | 
                  
| Supplier | 
                       Sony Biotechnology  | 
                  
| Dimensions | 
                       55 x 55 x 72cm  | 
                  
| RUO/Clinical | 
                       RUO  | 
                  
| Colors (up to) | 
                       6  | 
                  
| Lasers (up to) | 
                       3  | 
                  
| Laser Options | 
                       BYR  | 
                  
| Customizable | 
                       No  | 
                  
| Automation | 
                       Optional  | 
                  
| Max Sample # | 
                       0  | 
                  
| Sample Formats | 
                       Input: 0.5/1.5/5.0/15.0 mL tubes, Output: 1.5/5.0/15.0/50 mL tubes, multiwell plates  | 
                  
| Sample Cooling | 
                       Yes  | 
                  
| Events/Sec Max | 
                       100,000  | 
                  
| Measuring/Sort Time | 
                       Using the 70-μm sorting chip at 50 kHz, an average threshold of 12,000 events per second can be achieved with >98% purity and >80% yield. The threshold rate up to 30,000 events per second can be achieved without affecting purity but with a decrease in yield based on Poisson’s statistics.  | 
                  
| Detectors | 
                       8  | 
                  
| Detector Type | 
                       PMT  | 
                  
| Imaging | 
                       No  | 
                  
| Microfluidic | 
                       Yes  | 
                  
| Flat-top beam | 
                       No  | 
                  
| Colinear | 
                       Yes  | 
                  
Instrument Configuration
| 
                              LASER 488  | 
                              
                                  FILTERS
                                 525/50  | 
                              
                                 585/30  | 
                              
                                 617/30  | 
                              
                                 665/30  | 
                              
                                 720/60  | 
                              
                                 785/60  | 
                          
                    
                    