Description:
The BD Accuri™ C6 Plus Personal flow cytometer is the newest generation of the BD Accuri™ platform. Enhanced sensitivity, reliability, and capabilities bring flow cytometry even more within reach for new and experienced flow cytometry researchers. The BD Accuri C6 Plus supports a wide array of applications including immunology, cell and cancer biology, plant and microbiology, and industrial applications.
| Specifications | |
|---|---|
| Sorter/ Analyzer | 
                       Analyzers  | 
                  
| Supplier | 
                       BD Biosciences  | 
                  
| Dimensions | 
                       27.9 x 54.6 x 41.9cm  | 
                  
| RUO/Clinical | 
                       RUO  | 
                  
| Colors (up to) | 
                       4  | 
                  
| Lasers (up to) | 
                       2  | 
                  
| Laser Options | 
                       BR  | 
                  
| Customizable | 
                       No  | 
                  
| Automation | 
                       Yes  | 
                  
| Max Sample # | 
                       96  | 
                  
| Sample Formats | 
                       5 mL tubes or 48/96 well plates  | 
                  
| Events/Sec Max | 
                       10,000  | 
                  
| Flow Rate | 
                       10-100 uL/min  | 
                  
| Volume | 
                       50 ul minimum  | 
                  
| Measuring/Sort Time | 
                       < 90 minutes for 96-well plate, utilizing 30-second acquisition time per well  | 
                  
| Detectors | 
                       6  | 
                  
| Detector Type | 
                       PMT  | 
                  
| Sheath Bottle | 
                       2 L  | 
                  
| Imaging | 
                       No  | 
                  
| Microfluidic | 
                       No  | 
                  
| Flat-top beam | 
                       Yes  | 
                  
| Colinear | 
                       No  | 
                  
Instrument Configuration
| 
                              LASER 488  | 
                              
                                  FILTERS
                                 530/30  | 
                              
                                 585/42  | 
                              
                                 670LP  | 
                          
| 
                              LASER 635  | 
                              
                                  FILTERS
                                 661/16  | 
                          ||
                    
                    